REFERENCE · REACTIVE POWER COMPENSATION

Continuous control instead of steps:Active 100 kVA reactive power compensation with two NEXICONTROL converters

Two NEXICONTROL 400 050 COMP active compensators with continuous bidirectional control

Construction period: 2026 | Country: Slovakia

Active 100 kVA reactive power compensation with two NEXICONTROL converters

Customer challenge

Payments for reactive energy at the billing meter

VONSCH solution - turnkey

VONSCH products supplied
NEXICONTROL

Compensation is controlled directly from the billing metering. The RC-RS control system processes pulses from two billing meters through galvanic isolation and sets the reactive power of both converters according to the instantaneous demand.

We supplied two NEXICONTROL 400 050 COMP active compensators, 100 kVA in total, with a shared control system and reactive power metering. Control is continuous and bidirectional - the converters both supply and absorb reactive power as the instantaneous demand requires, without steps and without passive capacitor banks. Each converter controls within a range of ±50 kVAr. The IP55 units place no demands on switchroom space.

The control system sits in a separate RC-RS enclosure rated IP65. It communicates over Ethernet and RS485 through a Modbus gateway, operation is visible in the web visualization, and the equipment is accessible for remote management and service without a site visit.

Solution diagram
Scope of delivery (technical specification)
  • Consultation and assistance in designing the compensation
  • 2 pcs NEXICONTROL 400 050 COMP (100 kVA in total)
  • RC-RS control cabinet (IP65) with reactive power metering
  • Processing of pulses from two billing meters
  • Modbus gateway and remote access
  • Web visualization and remote management
  • Commissioning
  • Remote supervision

Project in numbers

100 kVA
installed active compensation power (2 pcs)
2 pcs
NEXICONTROL 400 050 COMP
±50 kVAr
continuous control range per unit

What the customer gained

  • Continuous bidirectional control of ±50 kVAr per unit instead of stepped capacitor banks
  • No passive components, hence no risk of resonance with the grid
  • Control taken directly from the billing meter pulses
  • IP55 rating, with no demands on switchroom space
  • Web visualization and remote supervision - service without a site visit

Why VONSCH

We reduce the risk of a wrong decision - from design to service you deal with a single partner who stands behind the solution.

  • A manufacturer, not a reseller - we develop and build power electronics in Brezno, Slovakia.
  • A turnkey solution - one responsibility from design through installation to commissioning.
  • Service and spare parts from Slovakia throughout the entire lifetime of the equipment.