Single-phase generator of required output electrical voltage with 60 Hz output frequency.
Artificial mains is used for compressor testing. Single phase AC output voltage is sensed by special measuring circuit which is connected as a feedback in output voltage control circuit. The output voltage setpoint is kept regardless of the load value. Desired voltage at the output is tuned by potentiometer within a specified range. Output AC voltage, current and frequency is displayed on the digital display. INPUT VOLTAGE: 3/PE/N ~ 50Hz 3x400V/TN-S OUTPUT
OUTPUT VOLTAGE: 2P + ~ 60Hz 100 ÷ 120V/TN-S
RATED CURRENT: Inin = 80A AC Inout = 142A AC
MAXIMUM CURRENT: IMAXout = 230A AC (to 2s)
CONTROL VOLTAGE: 230V AC, 24V
DC PROTECTION: IP 54/20
#NOFRONTPAGE#
Scope of Delivery
Technical solution
Project
Artificial AC mains
Certificate
Harmonic analysis of input current and output voltage and current
EMC disturbance measurement